SEL-735

SEL-735

Power Quality and Revenue Meter

The SEL-735 offers high-accuracy metering combined with detailed power quality analysis. With data available at their fingertips, operators can easily identify power system anomalies and mitigate their impact.For high-accuracy revenue metering applications, the SEL-735 exceeds ANSI C12.20 0.1 and IEC 62053-22 0.1 S accuracy class requirements over a wide current range. The SEL-735 maintains this accuracy through its entire service life, eliminating costs associated with field calibration. This makes the SEL-735 the premier choice for points of common coupling, interchanges, and critical loads.With optional continuous waveform streaming, the SEL-735 precisely samples and sends waveform data from the power system at 3 kilosamples per second (ksps).Accessories and Mounting Options

Starting at:

$2,150
View popular models

Ensure Accurate Revenue Metering

Exceed ANSI C12.20 0.1 and IEC 62053-22 0.1 S accuracy class requirements with bidirectional, full four-quadrant energy metering. Many new metering installations, such as distributed generation, operate over a wide current range. The SEL-735 accurately reports energy even in the presence of harmonics and distorted waveforms and provides high accuracy over an extended operating range. The SEL-735 will meet Class 0.1 accuracy requirements for its entire service life.

Compensate for Errors in Instrument Transformers

Increase metering accuracy by compensating for instrument transformer errors. The SEL-735 interpolates six user-defined calibration points and corrects ratio and phase errors over the entire measurement range. You can decrease replacement and maintenance costs by compensating for each instrument transformer individually.

Measure and Report Reliable Power Quality Indicators

Ensure precise and reliable measurements with IEC 61000-4-30 Class A power quality compliance. You can size feeders appropriately, safeguard equipment, and plan upgrades using power quality indicators for predictive maintenance. The SEL-735 measures harmonics, interharmonics, flicker, power factor, voltage disturbances, K-factor, and other key power quality indicators.

Load Profile Data

Collect billing data with a simple-to-use load profile recorder that captures years of data. Independent load profile recorders in the SEL-735 allow simultaneous meter and power quality logging of up to 512 analog channels for up to 20 years. The SEL-735 can trend averages, minimums, maximums, changes, and snapshots at a rate as often as every three seconds.

Stream and Record Waveform Data

The SEL-735 captures every disturbance in your power system. Optional continuous waveform streaming precisely samples voltage and current signals at 3 ksps and sends the data to SEL Synchrowave software for visualization.

Record Voltage Sag, Swell, and Interruption (VSSI) Data

Enabled from the factory, the VSSI recorder time-stamps voltage excursions with up to 4 ms resolution and records indefinitely using an adaptive sampling rate. Settings include trigger thresholds from ±3 percent to ±100 percent of the actual value and an automatic recording duration dependent on the length of the voltage excursion.

Streamline Commissioning, Testing, and Daily Use

View real-time metered quantities, phasor diagrams, voltage and current waveforms, and more with the intuitive always-on touchscreen display. Quickly navigate between applications and folders, set complex passwords, and configure settings without connecting a laptop. Speed up accuracy testing by visualizing test pulses, accumulated energy, and instantaneous signals.

Bundle Hardware and Software

Automate data retrieval, quickly visualize data, and create custom reports with the enterprise data collection and reporting software bundle, which includes Synchrowave Reports software. This combination of hardware and software simplifies ordering and license management, eliminates base license fees, and allows utilities to incrementally purchase the software device license for that meter. View software bundling options here.

Updates

Latest enhancements: continuous waveform streaming

The SEL-735 can now continuously stream waveform data at 3 ksps to SEL-5703 Synchrowave monitoring. Contact us for more information.

SEL-735 Features

  • Front—Touchscreen Version

  • Front—LCD Version

  • Back

  • Touchscreen—Real-Time Oscilloscope

  • Touchscreen—Phasor Diagrams

  • Touchscreen—Energy Metering

  • Touchscreen—Test Mode

  • Portable Power Quality Meter

  • Easily Extractable Meter

  • Outdoor Enclosure

  1. Capacitive 5-inch (12.7 cm) color touchscreen
  2. Continuous monitoring for all three power system phases; customizable screens that provide useful defaults, large fonts, and numerous choices for analog quantities
  3. Folders and applications to access information
  4. Six programmable LEDs
  5. USB Type-C port
  6. Simple Test Mode access
  7. Customizable local controls
1
2
3
4
5
6
7

Minimize the cost of harmonic mitigation with continuous waveform recording

David Renfro from Infiniti Integration Services describes SEL continuous waveform recording as the arbiter of truth and as a method for capturing all disturbances without custom event trigger logic. Learn how he optimizes filter designs for harmonics caused by variable-speed motor drives.

Continuous waveform streaming system

SEL-735 Details

Accurate Metering
The SEL-735 exceeds the requirements of ANSI and IEC accuracy standards over a wide current range. Capable of reliable and precise metering even in the presence of harmonics, the SEL-735 exceeds the 0.1 accuracy class requirements of ANSI C12.20 and 0.1 S accuracy class for IEC 62053-22. Quality-focused manufacturing ensures that the meter will meet these accuracy requirements throughout its service life.
Load Profile Data Collection
You can collect billing data with a simple-to-use load profile recorder that captures years of data.
Advanced Integration
The SEL-735 integrates seamlessly into Itron MV-90 billing software, IEC 61850, DNP3, IEEE C37.118, Modbus, or SEL communications architectures. Multiple communications ports and protocols enable the SEL-735 to simultaneously communicate with up to ten devices.
IEEE C37.118.1a-2014 Synchrophasors
Collect real-time measurements of electrical quantities, then use these data to perform wide-area control, validate system models, determine stability margins, maximize stable system loading, detect islanding, record system-wide disturbances, and visualize dynamic system responses. The synchrophasors in the SEL-735 adhere to IEEE C37.118.1a-2014, making them ideal for applications requiring fast response times under dynamic conditions.
Instrument Transformer Compensation
The SEL-735 is the only SEL product to provide both angular and magnitude compensation for instrument transformer errors. Correct delays and errors on each phase to achieve high-performance system accuracy, even when using protection-grade transformers. The SEL-735 is equipped with the powerful combination of IEEE C37.118 and Instrument Transformer Compensation (ITC), so you can choose to apply correction at either the synchrophasor interface or all metering interfaces, providing flexibility for many applications.
IEC 61850 GOOSE and MMS
Using IEC 61850 GOOSE, the SEL-735 can communicate peer to peer with another device to exchange metering, power quality, or control data in real time over Ethernet. Or, it can use MMS to report to an MMS client, such as a SCADA master.
Transformer and Line-Loss Compensation
By entering transformer nameplate and line impedance information directly into the meter, you can automatically compensate for transformer or line losses and move the billing point.
Time-of-Use (TOU) Metering
You can report flexible, time-differentiated energy and demand registers with multiple day types, rates, and seasons as well as a 20-year programmable calendar.
Predictive Demand
With the predictive demand function, you can monitor accumulated demand and alarm when the demand exceeds a user-defined limit. The SEL-735 can then shut down loads or peak-shave with generation to avoid demand charges. The predictive demand alarm is available through IEC 61850, Modbus, DNP3, Mirrored Bits communications, and the front-panel LEDs.
Software Integration Solutions
  • Configure Meters—acSELerator QuickSet SEL-5030 Software is an easy-to-use yet powerful tool with template design capabilities for easy, consistent settings and applications to help you get the most out of your SEL meter. Download QuickSet now.
  • Access Metering Data Conveniently—SEL-5703 Synchrowave Monitoring provides real-time and historic trending and archiving from events captured by the SEL-735. Synchrowave Reports lets you visualize high-resolution power system data and generate reports.
  • Analyze Event Data—SEL-5601-2 synchroWAVe Event Software displays SEL relay event reports and COMTRADE files, allowing you to easily analyze and diagnose relay behavior during a power system fault.
  • Take Action on Metering Data—Synchrowave Reports software visualizes the metering data collected and stored by SEL data retrieval software. With Synchrowave Reports, you can quickly analyze data, identify usage trends, and diagnose system problems.
  • Integrate Data Reporting—Representational state transfer (REST) application programming interfaces (APIs) integrate with enterprise-level systems, such as energy management systems and billing systems. Contact SEL for more details.
Power Quality and Recording Options
Choose from three power quality options to fit any application and budget. Click here to view option descriptions.
Continuous Waveform Streaming to Synchrowave at 3 ksps
Precisely samples voltage and current signals at 3 kilo samples per second (ksps) and sends to SEL Synchrowave software for data visualization.
Displays
Customizable three-line or single-line display
5-inch color touchscreen display, 800 × 480 pixels
Physical Chassis
Panel mount: horizontal or vertical with ANSI optical port or EIA-232 port
Easily Extractable Meter (EXM): vertical panel mount with ANSI optical port or EIA-232 port
Enclosure
16" x 18" NEMA 4 enclosure, wired to FT-1 test switch
Portable case with voltage clips
Front-panel sealing cover
Meter Form
Form 5, Form 36, or Form 9
Power Supply
12/24 Vdc, 24/48 Vdc, or 125/250 Vdc or Vac
Input Voltage (Vdc or Vac; includes 3 contact outputs and 2 inputs)
24, 48, 110, 125, 220, or 250
Communications
EIA-232 and EIA-485
USB Type-C
Ethernet: 10/100BASE-T, 100BASE-FX fiber-optic (available in multimode)
Communications Protocols
IEC 61850 with GOOSE and MMS
Enterprise Data Collection and Reporting Software Bundle
Bundle includes a one-unit license for:
For assistance, visit the SEL Software Licensing Information webpage or contact your local customer sales representative. Conformal-Coated Circuit Boards Flexible Mounting Options
A variety of bezels, brackets, enclosures, and rack-mount kits are available for quick, easy, and clean-looking retrofit installations and mounting flexibility. The SEL Metering Accessories Catalog offers a complete list of accessories. To view all the mounting options, visit the Mounting Selector  webpage.

Configuration

acSELerator QuickSet SEL-5030 Software

QuickSet is a tool for engineers and technicians to quickly and easily configure, commission, and manage power system devices. QuickSet includes a Graphical Logic Editor and a device template tool to reduce configuration time and streamline deployment. Learn more and download on the QuickSet software page.

acSELerator Architect SEL-5032 Software

Architect allows users to configure and document IEC 61850 systems that include GOOSE, Sampled Values (SV), or Manufacturing Message Specification (MMS) communications. Architect automatically compares SCL files with IEC 61850 requirements to ensure standard compliance. Learn more and download on the Architect software page.

Automated Data Collection

SEL Data Management and Automation (DMA) Application Suite

Available on the Blueframe platform, DMA applications automatically collect, store, and manage device-specific information like oscillography, Sequence of Events (SOE) data, device settings, and property information. They also provide automated password rotation and streamlined device audits. Learn more on the DMA software page.

Visualization and Analysis

SEL-5601-2 synchroWAVe Event Software

Synchrowave Event is an easy-to-use event report analytic software that helps engineers diagnose the cause of power system disturbances, including faults. Learn more and download on the synchroWAVe Event software page.

SEL-5705 Synchrowave Reports

Synchrowave Reports automates reporting of metering and power quality data via email or web browser. Quickly identify trends, harmonic disturbances, and other power quality concerns to drive planning, operating, and accounting decisions that will increase efficiency and reduce costs. Learn more and download on the Sychrowave Reports software page.
The table below indicates the software and features included in the Meter Data, Power Quality, and Energy and Power Monitoring ordering options.
 Meter Data OptionPower Quality OptionEnergy and Power Monitoring Option
acSELerator Team1   
Event and SER collection
LDP and VSSI collection
Synchrowave ReportsMeter Data ReportsPower Quality ReportsPower Quality Reports
Device Overview
SER
LDP
VSSI
Signals or WAGES
IEEE 519 Compliance Report 
Synchrowave Monitoring Trending and Archiving PackagePower Monitoring Package
Phasor Measurement Unit (PMU) 
Continuous Waveform Receiving 
Time-Series Historian 
Calculations 
Software PMU 
Virtual Metering 
Visualization 
Data Export 
Notifications/Alarms  
Oscillation Detection  
Disturbance Detection  
PT Failure Detection  
Threshold Monitoring  
1Both Meter Data and Power Quality options are available without a Team license if an application already has Team software available.
SEL-734 and SEL-735 Product Feature Comparison
The SEL-734 Revenue Meter is no longer in production. SEL recommends selecting the SEL-735 in place of the SEL-734.
SEL-735 Power Quality and Recording Options
Choose from three power quality options to fit any application and budget.
FeatureBasicIntermediateAdvanced
General
DisplayCustomizable three-line or single-line displayCustomizable three-line or single-line displayCustomizable three-line or single-line display; 5-inch 800 × 480 color touchscreen display*
Front PortANSI Type II optical port or EIA-232 portANSI Type II optical port or EIA-232 portANSI Type II optical port or EIA-232 port; Type-C USB*
Memory128 MB256 MB1 GB
Max Harmonic Order15th63rd63rd
Interharmonic QuantitiesNoNoYes
Harmonic AnglesNoNoYes
Power HarmonicsNoNoYes
Waveform Capture
Samples Per Cycle1616, 12816, 128, 512
Duration (cycles)1515–60015–600
Number of Events25633–6,200101–10,000
COMTRADE ReportsYesYesYes
Wave View OscillographyNoNoYes
Continuous Waveform Streaming to SynchrowaveUpgradableYesYes
Load Profile Data
Recorders × Channels1 × 1612 × 1632 × 16
Acquisition Rates1–120 min3–59 s, 1–120 min3–59 s, 1–120 min
Storage Duration0–10 years, varies with acquisition rate and number of channels used0–20 years, varies with acquisition rate and number of channels used0–20 years, varies with acquisition rate and number of channels used
Example Duration10 years for 16 channels logged every 10 min20 years for 16 channels logged every 10 min20 years for 16 channels logged every 10 min
Voltage Sag, Swell, Interruption (VSSI) Recorder
Typical Number of Summary Events270270600
Number of Detailed Rows60,00060,000>130,000
Minimum Disturbance Duration1/4 cycle1/4 cycle1/4 cycle
Sampling Rate4 samples/cycle–1 sample/day, adaptive4 samples/cycle–1 sample/day, adaptive4 samples/cycle–1 sample/day, adaptive
Sequential Events Recorder (SER)
Number of Events>80,000>80,000>80,000
Number of Channels Monitored≤72≤72≤72
IEC 61000-4-30 PQ Compliance
150/180-Cycle, 10-Minute, 2-Hour-Class AClass A
Flicker-Class A (10-min, 2-hr updates)Class A (1-min, 10-min, 2-hr updates)
Voltage Harmonics--Class A
Current Harmonics--Class A
*Optional feature

How a Data Center Achieves Utility-Grade Metering

Reducing Consumption to Serve the Community

Minimize the cost of harmonic mitigation with continuous waveform recording

Power Quality Theory

Metering Theory and Fundamentals

1 of 2
  • Power Quality Theory

  • SEL-735 Power Quality and Revenue Meter—Transformer and Line-Loss Compensation

SEL-735: Change Phase Rotation

How-to Commission the SEL-735 Meter

1 of 6
  • SEL-735: Change Phase Rotation

  • SEL-735: Form 5 Accuracy Testing

  • SEL-735: Meter Form Change

  • How to Surface Mount the SEL-735 Meter

  • How to Set SEL-735 Power Quality and Revenue Meter

  • How to Use SEL Easily Extractable Meters

SEL-735 Visualize System Losses

SEL-735 Meter Multifunction Display

1 of 3
  • SEL-735 Visualize System Losses

  • How to Set the SEL-735 With Color Touchscreen Display-Basic Settings

  • How to Use SEL-735 With Color Touchscreen Display-Overview

How to Use SEL-735 WAVE VIEW

Meter Reporting and Analysis

1 of 3
  • How to Use SEL-735 WAVE VIEW

  • How to Use acSELerator Meter Reports SEL-5630 Software

  • Customizing Reports in acSELerator Meter Reports Software

How to Set the SEL-735 Meter With DNP Map Settings

Meter Communication Settings

1 of 2
  • How to Set the SEL-735 Meter With DNP Map Settings

  • Pend Oreille Upgrades Substation With Innovative SEL RTAC, Axion, and Cabling Solution

Sales Resource Central access is required to view the content in this tab.