html{display:none} SEL-2407 and SEL-2488 Comparison | Schweitzer Engineering Laboratories

    SEL-2407 and SEL-2488 Comparison

    FeaturesSEL-2407SEL-2488
    Average Time Accuracy (demodulated IRIG-B and pulses) to UTC ±100 ns ±40 ns
    Peak Time Accuracy (demodulated IRIG-B and pulses) to UTC ±500 ns±100 ns
    Holdover Accuracy After 24 Hours at a Constant Temperature 6.9 ms 36 µs with standard TCXO, 5 µs with OCXO option, 2.5 µs with DOCXO option
    Demodulated IRIG-B Output PortsUp to 6 Up to 9
    Demodulated IRIG-B BNC Output Voltage and Cable Length 3.5 Vdc up to 130 ft5.0 Vdc up to 500 ft
    Modulated IRIG-B Ports Outputs 1 Up to 4
    Ethernet Ports 0 4 (can be copper, single-mode fiber, or multimode fiber, ordered in pairs)
    NTPv4 No Yes
    NTP Time-Stamp Accuracy (typical) to UTC  — <100 µs
    PTP Grandmaster (IEEE 1588) No Yes, with PTP option
    PTP Time-Stamp Accuracy (peak) to UTC ±100 ns
    PPS, kPPS Yes Yes
    10 MHz Frequency Output PortsNo 6 ports (optional) 
    ASCII Outputs Yes No
    Time Display Yes Yes
    Configurable Cable Delay Compensation No Yes
    Power Supplies 1 standard 1 standard; 1 optional redundant, hot-swappable
    Management Interface Serial Web
    Syslog No Yes
    Role-Based Accounts, LDAP Support No Yes
    SNMP Traps No Yes
    acSELerator QuickSet SEL-5030 Software Support No Yes
    Operating Temperature–40° to +80°C (–40° to +176°F) –40° to +85°C (–40° to +185°F)
    Time Source GPS GPS and GLONASS (for verification only)
    Recommended Antenna SEL-9524A SEL-9524B
    Antenna Cable Length Up to 400 ft Up to 500 ft
    Satellite Signal Verification No Yes, with SEL-9524B GNSS antenna kit 
    IEC 60255, IEC 61000, IEEE C37.90 Yes Yes
    IRIG-B Over Fiber Use optional fiber-optic serial port Use SEL-2812 or SEL-3405 with DB-9 port
    Alarm Contact Yes Yes

    Literature

    Documents sorted by newest first.

    Literature

    Publications

    Drawings